1. Product Overview

The canned motor pump is a leak-free pump that seals the pump and motor in the same pressure vessel. The motor rotor and pump impeller share a single shaft, separated from the stator by a non-magnetic thin-walled shielding sleeve.

Widely applicable to: Transfer of highly toxic, flammable/explosive, corrosive, radioactive, and precious liquids, such as LPG, refrigerants, toxic chemicals, etc.

Equipment features: Absolute zero leakage, no dynamic seals, compact structure, quiet operation, extremely high safety.

2. Working Principle

The magnetic field generated by the stator passes through the non-magnetic shielding sleeve to drive the rotor; the rotor shaft directly connects to the impeller; the pumped liquid is pressurized and discharged, while part of the liquid circulates inside the motor to remove heat; as the shielding sleeve completely isolates the stator windings from the pumped liquid, absolute zero leakage is achieved.

3. System Classification

By Medium Temperature

TypeTemp RangeCooling Method
Normal temp-10~100℃Internal liquid self-circulation
High temp100~350℃External heat exchanger forced cooling
Low temp-100~-10℃Low-temp anti-freeze design

4. Detailed Technical Parameters

4.1 Key Materials

ComponentMaterialRemarks
Body/Impeller304/316L/HastelloySelected by media corrosiveness
Shielding sleeveHastelloy C/Ti/SSThinner is better (0.3~0.5mm) to reduce losses
BearingCarbon graphite/SiC/PTFELubricated by the pumped liquid

4.2 Typical Specification Table

TypeFlow (m³/h)HeadPowerTemp RangeApplicable Media
Basic1~2005~1500.25~55kW-10~100℃Corrosive, toxic liquids
High temp1~1505~1201.5~45kW100~350℃Thermal oil, hot process liquid
High pressure1~10010~2502.2~55kW-40~100℃LPG/LNG

Note: Canned pump efficiency is usually 5-10% lower than standard centrifugal pumps; heat generation must be considered.

4.3 Design Conditions & Performance Indicators

ParameterSpecification
LeakageAbsolute zero
TRG monitoringStandard 3 or 6-digit TRG meter for bearing wear/rotor eccentricity
Motor temp riseStrictly controlled, usually with PTC thermistor
Noise≤70dB(A)
Protection classMotor part IP55+

4.4 Electrical Parameters

Applicable RegionVoltageFrequency
China/Russia/Central Asia380V50Hz
Middle East/SE Asia/Africa400V / 415V50Hz
South Korea380V60Hz
Americas (if needed)440V / 480V60Hz

5. Core Component Selection

ComponentCommon BrandsFeatures & Applications
Canned motorImport/Domestic specializedCustom design, Class H insulation
Shielding sleeveCustomHastelloy for corrosion, 0.3-0.5mm wall thickness
BearingSiC/GraphiteWear-resistant, must be compatible with media
Heat exchangerCustomEssential for high-temp type
TRG monitorStandardOnline condition monitoring, early warning

6. Typical Application Fields

Petrochemical: LPG, LNG transfer Refrigeration: Freon, ammonia transfer Chemical: Highly toxic, strong corrosive liquids Nuclear: Radioactive water circulation Pharmaceutical: High-purity solvent transfer

7. Design Standards & Certifications

StandardDescription
GB/T 26116-2010Canned motor technical conditions
API 685Sealless pump standard
ISO 9001:2015Quality Management System
CE / EAC / GOST-RAvailable upon request

8. Customizable Options

OptionDetails
Body material304/316L/Duplex/Hastelloy
Cooling methodSelf-circulation/Forced external (with cooler)
ConnectionFlange/Thread
InsulationExternal insulation layer on body
Control systemVFD, PLC interlock
Ex-proof req.Ex-proof canned pump (Ex d IIC T4)

9. Warranty Terms

Equipment StatusWarranty PeriodWarranty Scope
New Equipment12 MonthsShielding sleeve, bearings, body, motor windings
Refurbished Equipment6 MonthsShielding sleeve, bearings, body, motor windings
Idle Equipment (As-is)3 MonthsMain functional parts

Note: Sleeve and bearings are wear parts; damage from media incompatibility is not covered. Final terms subject to contract. All orders include installation guidance and remote debugging.

10. Packaging & Delivery

ItemPackaging Method
Canned pump unitWooden box, shock-absorbing
Heat exchanger (High temp)Wooden box
Accessories/InstrumentsWooden or carton box

Container Estimation: Small (≤5kW) approx. 5~10 units/20'GP; Medium (5~30kW) approx. 2~5 units/40'HQ. Installation: On-site guidance (strict wiring/exhaust procedures required).

11. Information Required for Quotation

Medium name, temp, density, volatile?; Flow, discharge pressure, NPSHa; Corrosiveness; Ex-proof?; Local voltage/frequency; Status: New/Refurbished/Idle; Terms: FOB/CIF/DDP; Destination port/address.